Diameter
Ft.9'
In.-
Length
Ft.34'
In.-
Pressure:217.5 PSI
Temperature:302 Deg. F.
Inventory
CAN BE CONVERTED INTO A COMPOSITE UNIT
Manufacturer: Maschinenbau Scholz.
Size: 9 8 .14 DIA. x 34 8.77 LONG
Pressure: 217.5 PSI
Temperature: 302 deg F
National Board#: ASME/National Board Certified Vessel; NB#225
Door:Two (2) Quick Opening Doors (each end) including mechanically operated cover looking device with limit switch as well as gripping device, in strict accordance with the regulations and the rules of the Professional Association, including Perhuna lip-type gasket as well as worm gear for turning the door electrically, including motor gear, coupling and limit switch, furthermore with weld-on dished end plate R= 0.8 p, the door complete with 2 handles 2 suspension devices for the lids Davit running on ball bearings for swinging off the lids electrically consisting of the motor gear, with pinion toothed wheel, curve guide and limit switch, and the electric control ready installed in the switch box.
Air Circulation: Consisting of the air guide channel and the 3 suction cones. The air distribution is perforated in the lower part.
Insulation: Interior insulation removable of 50 mm thickness, consisting of foil laminated, the insulation is covered by galvanized sheet steel covering
Cooling: With a total cooling surface of about 414 m2 made of special finned tubes installed in the upper suction cones.
Controls: Designed in strict accordance with the American Standards: Working voltage 460 v, 60 Hz, control voltage 120V, 60 Hz
Year: 1990
Construction: Carbon Steel
Availability: Immediate
Previous Use: Glass Lamination
Note: Information provided is based on information received from original owner. Prospective buyer must verify upon inspection
Contact person: Elsa Brown
E-mail: elsabrown@bondtech.net
Phone: 606-677-2616
Heating: The steam heating system has a heating surface of about 414 m2 made of special finned tubes installed in the upper suction cones. The radiator is made of steel. Steam Heating. Heating up with simultaneous pressurization 20 min
-Dwell time 20 min
-Cooling down 20 min
-Depressurazion 5 min
-Opening/closing of door 5 min
-Filling and discharging of material treated 5 min
-Total 75 min
-Heating up from 20 Dec. C up to 150 Deg. C within approximately 20 minutes.
-Cooling down from 150 Deg. C. to 60 Deg. C within approximately 20 minutes
-Filling weight Approximately 8000 Kg. Glass
-Approx. 1000 kg. Steel
-Cooling water consumption 85 m3/h at an inlet temperature of max 28 deg C. -For each fan approximately 0.5 m2/h
-Steam consumption: 3,000 kgs/h steam of 150 psi (183 Deg. C).
-Working voltage of the autoclave plant: 460 volt, 60 Hz
-Weight of the autoclave: 47,000 Kg.